Acoustic monitoring of a prestressed concrete beam reinforced by adhesively bonded composite - Centre d'études et d'expertise sur les risques, l'environnement, la mobilité et l'aménagement Accéder directement au contenu
Communication Dans Un Congrès Année : 2017

Acoustic monitoring of a prestressed concrete beam reinforced by adhesively bonded composite

Résumé

The use of adhesively bonded composite reinforcement is relatively widely used for concrete structures. Yet, some questions remain regarding its use in the case of prestressed concrete structures especially in relation with the influence of existing cracking and the verification of the encountered damage phenomena at real scale. French National Organism Cerema with the help of French motorway bridge owners association ASFA and French National Research Organism IFSTTAR realized several real size experimental investigations of an old prestressed concrete beam coming from a deconstructed bridge to answer these questions (Project CLERVAL). Both flexure and shear tests up to failure were carried out and several measurement methods were used to understand the role of the composite reinforcement on the behavior of the structure and the damage scenario. Acoustic emission was one of these methods and two different systems were investigated. The proposed communication will first describe the two used acoustic systems and their dedication. A specific development will then be presented aiming at optimizing the obtained acoustic phenomena localization. Finally, main results will then be presented for both flexure and shear tests. The obtained results are currently compiled with the results from the other measurement methods. This should allow to better understand the damage process of reinforced prestressed concrete beams and to assess the precision of existing reinforcement design methods.
Fichier principal
Vignette du fichier
doc00028112.pdf (917 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01639156 , version 1 (20-11-2017)

Identifiants

  • HAL Id : hal-01639156 , version 1

Citer

Sylvain Chataigner, Laurent Gaillet, Yannick Falaise, Jean-François David, Richard Michel, et al.. Acoustic monitoring of a prestressed concrete beam reinforced by adhesively bonded composite. SMAR 2017, the fourth International Conference on Smart Monitoring, Assessment and Rehabilitation of Civil Structures, Sep 2017, ZURICH, Switzerland. 8p. ⟨hal-01639156⟩
280 Consultations
131 Téléchargements

Partager

Gmail Facebook X LinkedIn More